Acne Soft Laser
The beginning of the treatment of acne vulgaris with laser optical systems is based on the following two steps: 1. reduction of infection and edema with destroying bacteria P. Acne
2. Long-term reduction in the production of sebum, with thermal effect in Sebaceous Gland
..........
This product meets the highest demands in terms of quality, functionality and design. When the drive is used correctly, an improvement in the condition will occur within a few days
The treatment may be repeated every month until Acne disappeared completely. The treatment must be done for 15 to 30 minutes a day 4 to 5 days of each month. The Acne Soft Laser can be used for the erpi which normally appears as a small bladders in the area around the lips, small wrinkle conditions and treatment in cases where a cold also new medical research shows that low-power laser can treat pain caused by osteo-arthritis and arthritis (following relative reference)

Technical Data:
Unit class: Low-level Laser class 3 A
Laser: GaALAs (Gallium-Aluminium-Arsenide) diode, continuous beam
Power output: Max. 6mW
Laser wavelength: 635-670nm
Power supply: 2×1.5 Valkaline batteries (“micro”: AAA/IEC Type LR 03)
Rated voltage: 3V DC
Operating mode: Continuous operation
Class of protection: internal supply
Explanation of symbols: Read Instructions for Use!
During the implementation of the laser must hold it 1 cm away from the skin if there are open wounds from the blains. The contact with the skin is allowed only when the blain has died. In the case that is used to reduce wrinkles and if there is no open wound may come into direct contact with the skin. In cases of antiviral effects hold also 1 cm away from the nose.
Its use is simple and effective.
Recommended for the proper care of the skin to combining various laser and peelings. The objective is to laser absorption of energy from the water in the epidermis, which are dulled the collagen fibres. The excitement of these fibres will lead to the production of new collagen, which is the aim. This process takes time in approximately six months. This method works best on recent scars edge and thicker wrinkle conditions.
ROMOPTO '94: Fourth Conference in Optics, Valentin I. Vlad, Editors, pp.420-421Date: 8 March 1995Paper Abstract557 patients with various noninflammatory rheumatism (osteoarthrosis and nonarticular) were treated in four different ways: with GaAs laser, 1 - 2 mW output power alone, with HeNe laser, 2 mW alone, with GaAs and HeNe together and with classical antiflammatory therapy.DOI: 10.1117/12.203590
Current SPIE Digital Library subscribers click here to download this paper.